How to choose the hotel downlight with good anti-glare lighting effect?

d9913d93e2da24cd1f2e20aa3aa1ad49
In hotel decoration, especially in high-end hotel decoration, special attention is paid to the design of lighting. Because the light can not only create a sense of atmosphere, but also assist in creating a comfortable sleeping environment.
A, the hotel downlight troubled
 
1, lighting power is too high, bright blind; power is too low, walking in the dark.
2, strobe is too high, so that people mental fatigue
3, light radiation area brightness is not uniform, some areas are clean and bright, some areas are dim and no light.
4, the light quality is not up to standard, only to “light up” the basic standard.
5, the installation and disassembly trouble, time-consuming and laborious post-maintenance.
 
Second, the role of downlighting in various areas of the hotel
 
First of all, we have to clarify the functional requirements of each area of the hotel for downlighting, in general, the hotel is divided into “high layer area” and “low layer area”, so we have to choose downlighting according to the characteristics of these two areas.
1, hotel vestibule, lobby, restaurant and other high-rise area, the height is usually H> 6m “high layer high area”, the LED downlight appeal lies in: embedded (and the environment blend, do not take over the main), high power, large diameter (large size), good anti-glare performance.
2, hotel corridors, guest rooms, bathrooms and other areas, the height of the H ≤ 2.8m “low height area”, the LED downlighting requirements are: embedded (appear ceiling clean, not compressed height), low power, small diameter (small size), good anti-glare performance.
 
Third, how to choose the right downlight for the hotel?
 
1. anti-glare lamps and lanterns: the bright place is bright, the light is not bright
① meet the requirements of the cut-off angle (cut-off angle > 30 °, and > 45 ° is good) of the downlight.
②Deeply hidden downlight
③With various anti-glare ring lamps and lanterns (including those by cutting light)
④Special processing optical reflector.
 
2. Luminaire with adjustable angle function
It not only increases the function of downlight, but also enables the ceiling cloth light to achieve regularity and enhance the multiple possibilities of space.
 
3. Relatively accurate beam angle
For the hotel space, the beam angle is one of the effective ways to build a sense of lighting hierarchy and atmosphere. LED luminaires era, there are differences in the beam angle of different brands. For LED luminaires used in hotel rooms, it is recommended to use medium narrow (15-18°), (medium beam 22-25°), and medium wide (28-30°), while hotel lobbies can use wide beam angles (55-60°), with different angles for different areas.
 
4. The light quality of the luminaire meets the standard
The light quality evaluation index of LED luminaire products: color temperature, color rendering, R9 value and color tolerance (SDCM), etc. And about the light quality requirements of LED downlight
 
5. Light spot clean and neat
Hotel space, whether it is a façade or a plane, must be neat and clean. Any disorderly light or shadow is very affect the visual effect, to create a soft and uniform light environment, the performance of the irradiated object itself does not have any meaning, therefore, a good light spot light type should be neat and beautiful, receding halo to transition natural.

ALUDS LIGHTING, the best offer of hotel deep anti-glare led downlights 
www.aludslighting.com

 
 
 


Post time: Mar-31-2022